Background
The Danfoss AK-SM 8xxA is a system manager for commercial refrigeration, used by supermarkets and food retailers to monitor and control cabinets, cold rooms and defrost cycles, with a web interface. CVE-2025-41450 is an improper authentication flaw (CWE-305) affecting AK-SM 8xxA firmware prior to version 4.2 (Danfoss advisory DSA-2025-03-01). CISA added it to KEV on 25 November 2026 with a due date of 9 December 2026.
Technical Mechanism
The sources describe this CVE differently:
- Danfoss DSA-2025-03-01 is titled “Improper Authentication … resulting in an authentication bypass” (CWE-305), while its description text refers to a web report that discloses sensitive information such as internal IP addresses, usernames and store names.
- DSA-2025-03-01’s description and the CISA KEV short description use that web-report wording, which matches the wording NVD uses for CVE-2023-25913 (our comparison). NVD’s own description of CVE-2025-41450 says only “Improper Authentication … prior to version 4.2”.
- Claroty Team82 (the original researchers) and a third-party repository, msuiche/fromagegate, describe a hidden “code-of-the-day” login bypass derived from the device date and accepted by
xml.cgi?action=getauth. The repository states Claroty redacted the algorithm and attribute names, and its PoCs run against an emulator using a stand-in algorithm.
The code-of-the-day mechanism is therefore sourced to Claroty and fromagegate, not to Danfoss, NVD or CISA. We cannot say from the sources which description matches the flaw CISA saw exploited.
Scores
| Source | CVSS 3.1 |
|---|---|
| NVD (primary) | 7.5, AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N |
| Danfoss (CNA, secondary) | 8.2, AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:H |
The cvssScore field uses the NVD value of 7.5; both scores are at or above 7.
Real-World Exploitation Evidence
- CISA KEV lists CVE-2025-41450 as exploited (added 25 November 2026; ransomware use “Unknown”). CISA-ADP SSVC: Exploitation active, Automatable no, Technical Impact partial. We did not find the underlying observations CISA used.
- FROMAGEGATE context: a researcher repository assigns the name FROMAGEGATE to an 11 to 12 October 2026 campaign in which Danfoss refrigeration controllers in French supermarkets were reportedly driven to defrost cycles and high temperatures (per that repository’s writeup, which is a single third-party source). That repository itself states that no source has named the flaw exploited and that linking it to CVE-2025-41450 is inference. Danfoss reportedly told AFP most affected devices were legacy products no longer receiving updates, which may point to an older product line. We therefore do not attribute the supermarket attack to this CVE.
Impact Assessment
Per NVD’s primary score (7.5), a network attacker with no privileges obtains a high confidentiality impact with no integrity or availability impact. Danfoss’s own CNA vector (8.2) adds low integrity and high availability impact and requires user interaction. If the Claroty-described login bypass applies, impact would be broader than either score reflects (our assessment). For a refrigeration controller, unauthorised access could enable spoilage of stock; neither the CVE description nor the advisory states this.
Affected Versions
| Product | Affected | Fixed |
|---|---|---|
| Danfoss AK-SM 8xxA Series | Prior to 4.2 | 4.2 |
Remediation Steps
- Upgrade AK-SM 8xxA firmware to version 4.2 or later using the Danfoss software download page. The researcher repository states that related flaws CVE-2025-41451 and CVE-2025-41452 were fixed in 4.3.1 (DSA-2025-08-01, which we did not open), so the newest release is preferable.
- Remove AK-SM interfaces from the internet; place them behind a VPN or firewall.
- Review access logs for logins from unknown sources and check for unexpected changes to setpoints and defrost schedules.
Detection Guidance
The researcher repository (describing the code-of-the-day mechanism) suggests: POST /xml.cgi?action=getauth with unexpected attributes or a short numeric date-derived password, sessions issued despite no valid configured credential, and firmware version banner exposure. Its Suricata and Sigma rules are explicitly for detection development, and the repository notes request schemas are reconstructions, so validate before deploying.
Timeline
| Date | Event |
|---|---|
| 2025 | Danfoss publishes DSA-2025-03-01 with fixed firmware 4.2 |
| 11-12 Oct 2026 | Reported attack on French supermarket refrigeration (flaw used unconfirmed) |
| 25 Nov 2026 | CISA adds CVE-2025-41450 to KEV |
| 26 Nov 2026 | This analysis published |
| 9 Dec 2026 | CISA KEV due date |